Flue gas steam boiler of medium pressure for heat utilization of flue gases, type VSKG. Automatic medium-pressure steam boiler using waste heat from internal combustion engines. The boiler has a two-pass design and two pipe bundles with inlet and outlet flue gas collectors. The working pressure of the boiler is 8 bar, and the temperature is 175 °C.
Feature
| Specification | VSKG 1000H | VSKG 1500H | VSKG 2300H | VSKG 4300H | |
|---|---|---|---|---|---|
| Steam output (at 105 °C feed water temperature) | t/h | 0.5 | 0.7 | 0.9 | 2.0 |
| Rated heat output | kW | 375 | 520 | 600 | 1430 |
| Boiler Efficiency without economizer | % | 90–92 | 90–92 | 90–92 | 90–92 |
| Flue gas temperature at the boiler inlet | ℃ | 450 | 420 | 380 | 450 |
| Wet flue gas volume | Nm3.h-1 | 4250 | 6730 | 9300 | 17800 |
| Operating steam pressure | bar | 10 | 10 | 10 | 10 |
| Maximum allowable steam pressure | bar | 13 | 13 | 13 | 13 |
| Test pressure | bar | 23 | 23 | 23 | 23 |
| Maximum allowable steam temperature | ℃ | 184 | 184 | 184 | 184 |
| Maximum allowable temperature | ℃ | 195 | 195 | 195 | 195 |
| Pressure loss on the flue gas side | mbar | 18 | 18 | 18 | 18 |
Feature
| Feature | VSKG 1000H | VSKG 1500H | VSKG 2300H | VSKG 4500H | |
|---|---|---|---|---|---|
| Shipping weight | kg | 3400 | 5700 | 7000 | 12000 |
| Water volume at minimum level | l | 2100 | 3340 | 3900 | 8100 |
| Steam volume from minimum water level | l | 1100 | 1250 | 1465 | 2230 |
| Total volume of the boiler | l | 3200 | 4590 | 5365 | 10330 |
| Flue gas inlet | ø mm | 750 | 840 | 1024 | 1000 |
| Flue gas outlet | mm | 630x400 | 710x450 | 900x480 | 1000 |
| Boiler inspection hatch | DN/mm | 200 | 200 | 200 | 200 |
Contact us today to learn how we can help you maximize energy utilization and reduce costs.
Contact Sales